Direct Bluetooth connection
Polar H10 connects directly to the smartphone or computer without a separate hardware gateway.
Polar H10 can be used with KardioAS as a compatible chest sensor for direct acquisition of a single-channel ECG signal and RR interval sequence.
The sensor connects directly by Bluetooth Low Energy to an Android smartphone or Windows computer. No additional controller, hardware gateway or intermediate device is required.
After recording, KardioAS stores the study and provides access to rhythm analysis, heart rate variability, ECG morphology, study comparison, parameter trends and report generation.
The current acquisition path is intentionally simple: Polar H10 → Bluetooth Low Energy → KardioAS. The sensor transmits data directly to the supported device, where the recording is stored as a study for later review and analysis.
Polar H10 connects directly to the smartphone or computer without a separate hardware gateway.
The session is stored as a study that can be reopened later instead of disappearing after the live screen closes.
The current Polar H10 workflow is available in the mobile and desktop KardioAS environments.
Core recording, analysis and study storage take place in the user-controlled environment.
KardioAS does not reduce the workflow to an average pulse value or a single score. The recorded study remains at the center of the analysis.
The chest-lead electrical signal is stored for visual review and subsequent software analysis.
The sequence of beat-to-beat intervals forms the basis for heart rate variability analysis.
Heart rate is interpreted together with the ECG trace and RR dynamics rather than as an isolated number.
The RR interval sequence can be used to examine several aspects of heart rate variability. KardioAS presents multiple analytical views rather than treating HRV as a single universal score.
Beat-to-beat variability can be summarized through standard time-domain characteristics.
Frequency-domain views provide an additional perspective on the structure of RR variability.
Poincaré and other nonlinear representations help visualize patterns that are not captured by a single scalar metric.
The recorded ECG remains available after the session for direct visual inspection and software-assisted analysis.
Review the recorded waveform itself instead of relying only on derived metrics.
Detected R peaks and beat structure provide the timing framework for rhythm and morphology analysis.
QRS-related characteristics and representative beat morphology can be examined when signal quality permits.
Signal quality matters. Morphological interpretation depends on electrode contact, motion artefacts, recording conditions and the characteristics of the individual study. Software-detected P, Q, R, S and T landmarks are available only when the signal quality supports reliable detection.
Because studies are saved, KardioAS can be used not only for viewing one session but also for repeated review and longitudinal observation.
Review results from different recordings in a consistent study structure.
Track selected parameters over time instead of interpreting every recording in isolation.
Reopen the source recording whenever a calculated result needs to be viewed in context.
Create structured reports for individual studies or longer-term trends.
Keep a consistent record of repeated measurements performed under comparable conditions.
Saved studies can be revisited as new comparisons or analytical questions arise.
KardioAS is designed around local recording, local analysis and user-controlled study storage. Core ECG and RR analysis does not require uploading the source recording to an external cloud service.
The Polar H10 + KardioAS combination can be relevant to users who need more information than a simple heart-rate display and who want to preserve the original study for later analysis.
Explore the structure of beat-to-beat intervals and heart rate variability across repeated recordings.
Inspect the recorded chest-sensor ECG together with the analytical context of the study.
Observe changes between recordings made under comparable conditions.
Review how selected physiological parameters change before, during or after repeated physical-load scenarios.
Keep structured records and export reports when documentation is required.
Use saved physiological signals for exploratory, educational and non-diagnostic analytical work.
Polar H10 is the current compatible sensor for the ECG/RR workflow described here. KardioAS is designed as an expandable analytical system rather than a product tied permanently to one sensor model.
The platform is being developed toward support for additional ECG sources, pulse-wave and PPG acquisition, and synchronized multi-signal studies as compatible acquisition modules are implemented and validated.
Polar H10 provides a single-channel signal from a chest-electrode configuration. This can be useful for rhythm, RR-interval and selected morphology analysis, but it is substantially different from a standard diagnostic 12-lead ECG.
If symptoms occur or there are concerns about health status, the appropriate action is to seek assessment from a qualified medical professional.
Polar H10 is a third-party compatible sensor. KardioAS™ is an independent product and is not affiliated with, endorsed by or developed by Polar Electro.
Polar H10 hardware is purchased separately from KardioAS. For users in Lithuania, current retailer offers can be compared through Kaina24.lt. Official sensor specifications and product information are available directly from Polar.
Compare current offers from Lithuanian retailers in one place. Availability and prices are determined by the individual sellers and may change.
Compare on Kaina24.lt ↗View the manufacturer’s product page for current technical specifications, connectivity details and official product information.
View Polar H10 at Polar.com ↗KardioAS is not affiliated with Kaina24.lt or the retailers listed there. External links are provided for user convenience and product information only.
Yes. Polar H10 is the currently supported chest sensor for the ECG and RR acquisition workflow described on this page. The sensor hardware is purchased separately from KardioAS.
No. In the current workflow, Polar H10 connects directly by Bluetooth Low Energy to a supported Android device or Windows computer.
Core recording, study storage and analysis are designed to run locally. An external cloud service is not required for the core analytical workflow.
No. Polar H10 provides a single non-standard chest-sensor ECG channel, which is substantially different from a diagnostic 12-lead ECG.
No. KardioAS is an independent software product. Polar H10 is used as a compatible third-party sensor.